Hammond Q002ERCF Buck Boost Transformer HT2923

$260.93
In stock
SKU
HT2923
Shipping: $33.38 via Ground
120x240 Volts Primary, 12x24 Volts Secondary, 2 kVA, 50/60 Hz, 1 Phase, NEMA 3R Encapsulated
Specifications View more Close tab
More Information
TEMCo ID HT2923
Transformer Type Buck Boost
Input Voltage 120x240
Output Voltage 12x24
Phase Single
Frequency (Hz) 50/60
kVA 2
K Rating 1
Primary Configuration Two Winding
Secondary Configuration Two Winding
Winding Material Copper
Temperature Rise (°C) 115
Insulation System (°C) 180
Enclosure Rating NEMA 3R
Enclosure Material Steel
Construction Style Enclosed - Encapsulated Core & Coil
Mounting Type Wall
Connection Type Wire leads
Cooling Air/Dry
Sound Level (dB) 36 dB
Length (in) 6.5
Width (in) 7
Height (in) 11.75
Weight (lb) 46
Warranty 10 Years
Product Description View more Close tab
Equivalent Buck-Boost Transformer Models
Manufacturer Same Size Next Larger Next Smaller
Acme AT1474 AT1475 AT1473
Federal FT0068 FT0069 FT0067
Hammond HT2923 HT2933 HT2981
GE GT1104 GT1105 GT1103

This versatile transformer will produce any of the below voltage combinations. Verify that your application falls under the capactiy given in amps or kVA for the voltage combination selected. If you would like to increase or reduce the capacity beyond what this model offers, see the Equivalent Models table above.


Boost Voltage (Increase) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
96 115 9.58 83.3 2 - view »
100 110 18.3 166 1 - view »
100 120 10 83.3 2 - view »
105 115 19.2 166 1 - view »
110 121 20.1 166 1 - view »
110 132 11 83.3 2 - view »
115 126 21 166 1 - view »
115 138 11.5 83.3 2 - view »
120 132 22 166 1 - view »
120 144 12 83.3 2 - view »
200 220 18.3 83.3 4 - view »
208 229 19 83.3 4 - view »
220 231 38.5 166 3 - view »
220 242 20.1 83.3 4 - view »
240 252 42 166 3 - view »
240 264 22 83.3 4 - view »
Buck Voltage (Reduce) - SINGLE PHASE
Input Volts Output Volts kVA Amps Connection Diagram
115 96 9.58 99.8 2 - view »
110 100 18.3 183 1 - view »
120 100 10 100 2 - view »
115 105 19.2 183 1 - view »
121 110 20.1 183 1 - view »
132 110 11 100 2 - view »
126 115 21 183 1 - view »
138 115 11.5 100 2 - view »
132 120 22 183 1 - view »
144 120 12 100 2 - view »
220 200 18.3 91.7 4 - view »
229 208 19 91.7 4 - view »
231 220 38.5 175 3 - view »
242 220 20.1 91.6 4 - view »
252 240 42 175 3 - view »
264 240 22 91.6 4 - view »


Boost Voltage (Increase) - THREE PHASE
Input Volts Output Volts kVA Amps Qty Required Connection Diagram
189 208 30 83.3 2 7 - view »
198 208 60 167 2 8 - view »
208 218 63.1 167 2 8 - view »
208 229 33 83.3 2 7 - view »
220 242 34.9 83.3 2 7 - view »
227 250 36.1 83.3 2 7 - view »
228 239 69.1 167 2 8 - view »
232 255 36.8 83.3 2 7 - view »
240 264 38.1 83.3 2 7 - view »
189Y109 208Y120 60 167 3 10 - view »
199Y115 239Y138 34.5 83.3 3 9 - view »
208Y120 229Y132 66 167 3 10 - view »
379Y219 417Y241 60.3 83.3 3 12 - view »
416Y240 436Y252 126 167 3 11 - view »
416Y240 457Y264 66 83.3 3 12 - view »
Buck Voltage (Decrease) - THREE PHASE
Input Volts Output Volts kVA Amps Qty Required Connection Diagram
208 189 30 91.7 2 7 - view »
208 198 60 175 2 8 - view »
218 208 63.1 175 2 8 - view »
229 208 33 91.7 2 7 - view »
242 220 34.9 91.7 2 7 - view »
250 227 36.1 91.7 2 7 - view »
239 228 69.1 175 2 8 - view »
255 232 36.8 91.7 2 7 - view »
264 240 38.1 91.7 2 7 - view »
208Y120 189Y109 60 183 3 10 - view »
239Y138 199Y115 34.5 100 3 9 - view »
229Y132 208Y120 66 183 3 10 - view »
417Y241 379Y219 60.3 91.7 3 12 - view »
436Y252 416Y240 126 175 3 11 - view »
457Y264 416Y240 66 91.7 3 12 - view »

NOTE: Y configured units must have Y supply for proper operation.