WEG SSW060820T2257ESZ Soft Starter S60018 - 3 Phase, 350 HP 230V / 700 HP 460V / 850 HP 575V, 820 Amp

$8,593.20
In stock
SKU
S60018
Shipping: FREE via Ground
WEG SSW06 Series Soft Starter.
Specifications View more Close tab
More Information
TEMCo IDS60018
Manufacturer Part NumberSSW060820T2257ESZ
Voltage230/460/575
Horsepower350 at 230V, 700 at 460V, 850 at 575V
PhaseThree
Frequency (Hz)50/60
Full Load Amperage820
Starts Per Hour10
Enclosure RatingIP00
Programmable Digital Inputs5
Programmable Relay Outputs3
Agency ApprovalscUL Listed, CE Marked
Length (in)15
Width (in)22
Height (in)32
Weight (lb)265
Warranty18 Months
Support Information View more Close tab
Manual
pdf
(Size: 1.4 MB)
Related Information View more Close tab
Product Description View more Close tab

The SSW06 is WEG's third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation once the motor is at full voltage, which makes it extremely compact and allows for simple integration into non ventilated enclosures and replacement of electro-mechanical starters in Motor Control Centers.

Standard Features

  • 200 - 600V, 50/60Hz input power supply
  • Built-in run rated (AC1) bypass contactor up to 820A*
  • Rated 450% current
  • Conformal coated circuit board
  • Voltage ramp or current limit start modes
  • Detachable keypad with dual display (LCD and LED) and copy function
  • 90 - 250 VAC auxiliary control voltage
  • Single 32 bit RISC processor based control board
  • IP00 protected chassis enclosure
  • Six isolated 24 VDC programmable digital inputs
  • Three programmable relay outputs (2 Amp - 250V)
  • One 0 - 10 VDC programmable analog output
  • One 4 - 20 mA programmable analog output
  • Motor PTC thermistor input
  • RS-232 serial interface
  • Adjustable acceleration and deceleration ramps (1 - 299 seconds)
  • Adjustable pedestal voltage (25 - 90% of line voltage)
  • Diagnostic features: Motor overload, over current and phase loss, motor immediate over and under current, SCR over temperature and fault, line phase loss and phase sequence, line over and under voltage
  • Display readings: Motor current, voltage, kW and power factor, line voltage and frequency, four last fault trips, run and power-up timers
  • Ambient: 32°F (0°C) to 131°F (55°C), 3300 ft (1000m) altitude, 90% non-condensing humidity

*SSW06 950A, 1100A, and 1400A units do not include integrated AC1 bypass.

Write Your Own Review