600 Wye V Primary Three Phase Control Transformers
TEMCo's three phase control transformers are copper wound and built with heat-proof insulation for compact size and long life. Wiring is made easy by the solidly fixed terminals with standard combination slotted Robertson head screw connections. Bobbin-wound coils provide better efficiency, great heat evacuation, and compact structure. These units are built to last, guaranteed, backed with a 10 Year Warranty.
Looking for a different specification? Check out our link to our 3 phase control transformer selection guide on the right of this page. We carry thousands of models in all kinds of configurations.
Product Features
• UL Listed
• CSA Approved
• Copper windings
• 1 to 3 week build time
• Soldily fixed terminals with standard combination slotted Robertson head screw connections facilitate wiring.
• Built with heat-proof insulation for compact size and long life.
• Unique bobbin-wound coils for greater efficiency, superior heat evacuation, and compact structure.
Select a different Primary configuration »
| Secondary Voltages Selection | |
| 110 » | 105Y/61 » |
| 120 » | 110Y/64 » |
| 208 » | 120Y/69 » |
| 220 » | 120/240 » |
| 230 » | 208Y/120 » |
| 236 » | 220Y/127 » |
| 240 » | 230Y/133 » |
| 347 » | 240Y/139 » |
| 360 » | 380Y/220 » |
| 380 » | 400Y/231 » |
| 400 » | 380/400/415Y » |
| 415 » | 416Y/240 » |
| 440 » | 460Y/266 » |
| 460 » | 480Y/277 » |
| 480 » | 600Y/347 » |
| 575 » | 600 » |
110 V Secondary
600V Wye primary (input) x 110 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 110 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 110 | 1.84 | Contact | Contact | Contact | Contact |
| 0.50 | 110 | 2.62 | Contact | Contact | Contact | Contact |
| 0.75 | 110 | 3.94 | Contact | Contact | Contact | Contact |
| 1.00 | 110 | 5.25 | Contact | Contact | Contact | Contact |
| 1.50 | 110 | 7.87 | Contact | Contact | Contact | Contact |
| 2.00 | 110 | 10.5 | Contact | Contact | Contact | Contact |
| 3.00 | 110 | 15.75 | Contact | Contact | Contact | Contact |
105Y/61 V Secondary
600V Wye primary (input) x 105Y/61 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 105Y/61 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 105Y/61 | 1.92 | Contact | Contact | Contact | Contact |
| 0.50 | 105Y/61 | 2.75 | Contact | Contact | Contact | Contact |
| 0.75 | 105Y/61 | 4.12 | Contact | Contact | Contact | Contact |
| 1.00 | 105Y/61 | 5.5 | Contact | Contact | Contact | Contact |
| 1.50 | 105Y/61 | 8.25 | Contact | Contact | Contact | Contact |
| 2.00 | 105Y/61 | 11 | Contact | Contact | Contact | Contact |
| 3.00 | 105Y/61 | 16.5 | Contact | Contact | Contact | Contact |
120 V Secondary
600V Wye primary (input) x 120 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 120 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 120 | 1.68 | Contact | Contact | Contact | Contact |
| 0.50 | 120 | 2.41 | Contact | Contact | Contact | Contact |
| 0.75 | 120 | 3.61 | Contact | Contact | Contact | Contact |
| 1.00 | 120 | 4.81 | Contact | Contact | Contact | Contact |
| 1.50 | 120 | 7.22 | Contact | Contact | Contact | Contact |
| 2.00 | 120 | 9.62 | Contact | Contact | Contact | Contact |
| 3.00 | 120 | 14.43 | Contact | Contact | Contact | Contact |
110Y/64 V Secondary
600V Wye primary (input) x 110Y/64 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 110Y/64 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 110Y/64 | 1.84 | Contact | Contact | Contact | Contact |
| 0.50 | 110Y/64 | 2.62 | Contact | Contact | Contact | Contact |
| 0.75 | 110Y/64 | 3.94 | Contact | Contact | Contact | Contact |
| 1.00 | 110Y/64 | 5.25 | Contact | Contact | Contact | Contact |
| 1.50 | 110Y/64 | 7.87 | Contact | Contact | Contact | Contact |
| 2.00 | 110Y/64 | 10.5 | Contact | Contact | Contact | Contact |
| 3.00 | 110Y/64 | 15.75 | Contact | Contact | Contact | Contact |
208 V Secondary
600V Wye primary (input) x 208 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 208 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 208 | 0.97 | Contact | Contact | Contact | Contact |
| 0.50 | 208 | 1.39 | Contact | Contact | Contact | Contact |
| 0.75 | 208 | 2.08 | Contact | Contact | Contact | Contact |
| 1.00 | 208 | 2.78 | Contact | Contact | Contact | Contact |
| 1.50 | 208 | 4.16 | Contact | Contact | Contact | Contact |
| 2.00 | 208 | 5.55 | Contact | Contact | Contact | Contact |
| 3.00 | 208 | 8.33 | Contact | Contact | Contact | Contact |
120Y/69 V Secondary
600V Wye primary (input) x 120Y/69 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 120Y/69 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 120Y/69 | 1.68 | Contact | Contact | Contact | Contact |
| 0.50 | 120Y/69 | 2.41 | Contact | Contact | Contact | Contact |
| 0.75 | 120Y/69 | 3.61 | Contact | Contact | Contact | Contact |
| 1.00 | 120Y/69 | 4.81 | Contact | Contact | Contact | Contact |
| 1.50 | 120Y/69 | 7.22 | Contact | Contact | Contact | Contact |
| 2.00 | 120Y/69 | 9.62 | Contact | Contact | Contact | Contact |
| 3.00 | 120Y/69 | 14.43 | Contact | Contact | Contact | Contact |
220 V Secondary
600V Wye primary (input) x 220 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 220 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 220 | 0.92 | Contact | Contact | Contact | Contact |
| 0.50 | 220 | 1.31 | Contact | Contact | Contact | Contact |
| 0.75 | 220 | 1.97 | Contact | Contact | Contact | Contact |
| 1.00 | 220 | 2.62 | Contact | Contact | Contact | Contact |
| 1.50 | 220 | 3.94 | Contact | Contact | Contact | Contact |
| 2.00 | 220 | 5.25 | Contact | Contact | Contact | Contact |
| 3.00 | 220 | 7.87 | Contact | Contact | Contact | Contact |
120/240 V Secondary
600V Wye primary (input) x 120/240 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 120/240 Delta Secondary (with center tap) | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 120,240 | 1.68, 0.84 | Contact | Contact | Contact | Contact |
| 0.50 | 120,240 | 2.41, 1.2 | Contact | Contact | Contact | Contact |
| 0.75 | 120,240 | 3.61, 1.8 | Contact | Contact | Contact | Contact |
| 1.00 | 120,240 | 4.81, 2.41 | Contact | Contact | Contact | Contact |
| 1.50 | 120,240 | 7.22, 3.61 | Contact | Contact | Contact | Contact |
| 2.00 | 120,240 | 9.62, 4.81 | Contact | Contact | Contact | Contact |
| 3.00 | 120,240 | 14.43, 7.22 | Contact | Contact | Contact | Contact |
230 V Secondary
600V Wye primary (input) x 230 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 230 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 230 | 0.88 | Contact | Contact | Contact | Contact |
| 0.50 | 230 | 1.26 | Contact | Contact | Contact | Contact |
| 0.75 | 230 | 1.88 | Contact | Contact | Contact | Contact |
| 1.00 | 230 | 2.51 | Contact | Contact | Contact | Contact |
| 1.50 | 230 | 3.77 | Contact | Contact | Contact | Contact |
| 2.00 | 230 | 5.02 | Contact | Contact | Contact | Contact |
| 3.00 | 230 | 7.53 | Contact | Contact | Contact | Contact |
208 V Secondary
600V Wye Primary (input) x 208Y120 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 208Y120 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 208Y/120 | 0.97 | Contact | Contact | Contact | Contact |
| 0.50 | 208Y/120 | 1.39 | Contact | Contact | Contact | Contact |
| 0.75 | 208Y/120 | 2.08 | Contact | Contact | Contact | Contact |
| 1.00 | 208Y/120 | 2.78 | Contact | Contact | Contact | Contact |
| 1.50 | 208Y/120 | 4.16 | Contact | Contact | Contact | Contact |
| 2.00 | 208Y/120 | 5.55 | Contact | Contact | Contact | Contact |
| 3.00 | 208Y/120 | 8.33 | Contact | Contact | Contact | Contact |
236 V Secondary
600V Wye primary (input) x 236 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 236 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 236 | 0.86 | Contact | Contact | Contact | Contact |
| 0.50 | 236 | 1.22 | Contact | Contact | Contact | Contact |
| 0.75 | 236 | 1.83 | Contact | Contact | Contact | Contact |
| 1.00 | 236 | 2.45 | Contact | Contact | Contact | Contact |
| 1.50 | 236 | 3.67 | Contact | Contact | Contact | Contact |
| 2.00 | 236 | 4.89 | Contact | Contact | Contact | Contact |
| 3.00 | 236 | 7.34 | Contact | Contact | Contact | Contact |
220Y/127 V Secondary
600V Wye primary (input) x 220Y/127 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 220Y/127 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 220Y/127 | 0.92 | Contact | Contact | Contact | Contact |
| 0.50 | 220Y/127 | 1.31 | Contact | Contact | Contact | Contact |
| 0.75 | 220Y/127 | 1.97 | Contact | Contact | Contact | Contact |
| 1.00 | 220Y/127 | 2.62 | Contact | Contact | Contact | Contact |
| 1.50 | 220Y/127 | 3.94 | Contact | Contact | Contact | Contact |
| 2.00 | 220Y/127 | 5.25 | Contact | Contact | Contact | Contact |
| 3.00 | 220Y/127 | 7.87 | Contact | Contact | Contact | Contact |
240 V Secondary
600V Wye primary (input) x 240 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 240 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 240 | 0.84 | Contact | Contact | Contact | Contact |
| 0.50 | 240 | 1.2 | Contact | Contact | Contact | Contact |
| 0.75 | 240 | 1.8 | Contact | Contact | Contact | Contact |
| 1.00 | 240 | 2.41 | Contact | Contact | Contact | Contact |
| 1.50 | 240 | 3.61 | Contact | Contact | Contact | Contact |
| 2.00 | 240 | 4.81 | Contact | Contact | Contact | Contact |
| 3.00 | 240 | 7.22 | Contact | Contact | Contact | Contact |
230Y/133 V Secondary
600V Wye primary (input) x 230Y/133 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 230Y/133 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 230Y/133 | 0.88 | Contact | Contact | Contact | Contact |
| 0.50 | 230Y/133 | 1.26 | Contact | Contact | Contact | Contact |
| 0.75 | 230Y/133 | 1.88 | Contact | Contact | Contact | Contact |
| 1.00 | 230Y/133 | 2.51 | Contact | Contact | Contact | Contact |
| 1.50 | 230Y/133 | 3.77 | Contact | Contact | Contact | Contact |
| 2.00 | 230Y/133 | 5.02 | Contact | Contact | Contact | Contact |
| 3.00 | 230Y/133 | 7.53 | Contact | Contact | Contact | Contact |
347 V Secondary
600V Wye primary (input) x 347 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 347 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 347 | 0.58 | Contact | Contact | Contact | Contact |
| 0.50 | 347 | 0.83 | Contact | Contact | Contact | Contact |
| 0.75 | 347 | 1.25 | Contact | Contact | Contact | Contact |
| 1.00 | 347 | 1.66 | Contact | Contact | Contact | Contact |
| 1.50 | 347 | 2.5 | Contact | Contact | Contact | Contact |
| 2.00 | 347 | 3.33 | Contact | Contact | Contact | Contact |
| 3.00 | 347 | 4.99 | Contact | Contact | Contact | Contact |
240Y/139 V Secondary
600V Wye primary (input) x 240Y/139 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 240Y/139 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 240Y/139 | 0.84 | Contact | Contact | Contact | Contact |
| 0.50 | 240Y/139 | 1.2 | Contact | Contact | Contact | Contact |
| 0.75 | 240Y/139 | 1.8 | Contact | Contact | Contact | Contact |
| 1.00 | 240Y/139 | 2.41 | Contact | Contact | Contact | Contact |
| 1.50 | 240Y/139 | 3.61 | Contact | Contact | Contact | Contact |
| 2.00 | 240Y/139 | 4.81 | Contact | Contact | Contact | Contact |
| 3.00 | 240Y/139 | 7.22 | Contact | Contact | Contact | Contact |
360 V Secondary
600V Wye primary (input) x 360 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 360 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 360 | 0.56 | Contact | Contact | Contact | Contact |
| 0.50 | 360 | 0.8 | Contact | Contact | Contact | Contact |
| 0.75 | 360 | 1.2 | Contact | Contact | Contact | Contact |
| 1.00 | 360 | 1.6 | Contact | Contact | Contact | Contact |
| 1.50 | 360 | 2.41 | Contact | Contact | Contact | Contact |
| 2.00 | 360 | 3.21 | Contact | Contact | Contact | Contact |
| 3.00 | 360 | 4.81 | Contact | Contact | Contact | Contact |
380Y/220 V Secondary
600V Wye primary (input) x 380Y/220 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 380Y/220 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 380Y/220 | 0.53 | Contact | Contact | Contact | Contact |
| 0.50 | 380Y/220 | 0.76 | Contact | Contact | Contact | Contact |
| 0.75 | 380Y/220 | 1.14 | Contact | Contact | Contact | Contact |
| 1.00 | 380Y/220 | 1.52 | Contact | Contact | Contact | Contact |
| 1.50 | 380Y/220 | 2.28 | Contact | Contact | Contact | Contact |
| 2.00 | 380Y/220 | 3.04 | Contact | Contact | Contact | Contact |
| 3.00 | 380Y/220 | 4.56 | Contact | Contact | Contact | Contact |
380 V Secondary
600V Wye primary (input) x 380 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 380 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 380 | 0.53 | Contact | Contact | Contact | Contact |
| 0.50 | 380 | 0.76 | Contact | Contact | Contact | Contact |
| 0.75 | 380 | 1.14 | Contact | Contact | Contact | Contact |
| 1.00 | 380 | 1.52 | Contact | Contact | Contact | Contact |
| 1.50 | 380 | 2.28 | Contact | Contact | Contact | Contact |
| 2.00 | 380 | 3.04 | Contact | Contact | Contact | Contact |
| 3.00 | 380 | 4.56 | Contact | Contact | Contact | Contact |
400Y/231 V Secondary
600V Wye primary (input) x 400Y/231 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 400Y/231 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 400Y/231 | 0.51 | Contact | Contact | Contact | Contact |
| 0.50 | 400Y/231 | 0.72 | Contact | Contact | Contact | Contact |
| 0.75 | 400Y/231 | 1.08 | Contact | Contact | Contact | Contact |
| 1.00 | 400Y/231 | 1.44 | Contact | Contact | Contact | Contact |
| 1.50 | 400Y/231 | 2.17 | Contact | Contact | Contact | Contact |
| 2.00 | 400Y/231 | 2.89 | Contact | Contact | Contact | Contact |
| 3.00 | 400Y/231 | 4.33 | Contact | Contact | Contact | Contact |
400 V Secondary
600V Wye primary (input) x 400 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 400 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 400 | 0.51 | Contact | Contact | Contact | Contact |
| 0.50 | 400 | 0.72 | Contact | Contact | Contact | Contact |
| 0.75 | 400 | 1.08 | Contact | Contact | Contact | Contact |
| 1.00 | 400 | 1.44 | Contact | Contact | Contact | Contact |
| 1.50 | 400 | 2.17 | Contact | Contact | Contact | Contact |
| 2.00 | 400 | 2.89 | Contact | Contact | Contact | Contact |
| 3.00 | 400 | 4.33 | Contact | Contact | Contact | Contact |
380/400/415Y V Secondary
600V Wye primary (input) x 380/400/415Y secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 380/400/415Y Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 380,400,415Y | 0.53, 0.51, 0.49 | Contact | Contact | Contact | Contact |
| 0.50 | 380,400,415Y | 0.76, 0.72, 0.7 | Contact | Contact | Contact | Contact |
| 0.75 | 380,400,415Y | 1.14, 1.08, 1.04 | Contact | Contact | Contact | Contact |
| 1.00 | 380,400,415Y | 1.52, 1.44, 1.39 | Contact | Contact | Contact | Contact |
| 1.50 | 380,400,415Y | 2.28, 2.17, 2.09 | Contact | Contact | Contact | Contact |
| 2.00 | 380,400,415Y | 3.04, 2.89, 2.78 | Contact | Contact | Contact | Contact |
| 3.00 | 380,400,415Y | 4.56, 4.33, 4.17 | Contact | Contact | Contact | Contact |
415 V Secondary
600V Wye primary (input) x 415 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 415 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 415 | 0.49 | Contact | Contact | Contact | Contact |
| 0.50 | 415 | 0.7 | Contact | Contact | Contact | Contact |
| 0.75 | 415 | 1.04 | Contact | Contact | Contact | Contact |
| 1.00 | 415 | 1.39 | Contact | Contact | Contact | Contact |
| 1.50 | 415 | 2.09 | Contact | Contact | Contact | Contact |
| 2.00 | 415 | 2.78 | Contact | Contact | Contact | Contact |
| 3.00 | 415 | 4.17 | Contact | Contact | Contact | Contact |
416Y/240 V Secondary
600V Wye primary (input) x 416Y/240 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 416Y/240 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 416Y/240 | 0.49 | Contact | Contact | Contact | Contact |
| 0.50 | 416Y/240 | 0.69 | Contact | Contact | Contact | Contact |
| 0.75 | 416Y/240 | 1.04 | Contact | Contact | Contact | Contact |
| 1.00 | 416Y/240 | 1.39 | Contact | Contact | Contact | Contact |
| 1.50 | 416Y/240 | 2.08 | Contact | Contact | Contact | Contact |
| 2.00 | 416Y/240 | 2.78 | Contact | Contact | Contact | Contact |
| 3.00 | 416Y/240 | 4.16 | Contact | Contact | Contact | Contact |
440 V Secondary
600V Wye primary (input) x 440 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 440 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 440 | 0.46 | Contact | Contact | Contact | Contact |
| 0.50 | 440 | 0.66 | Contact | Contact | Contact | Contact |
| 0.75 | 440 | 0.98 | Contact | Contact | Contact | Contact |
| 1.00 | 440 | 1.31 | Contact | Contact | Contact | Contact |
| 1.50 | 440 | 1.97 | Contact | Contact | Contact | Contact |
| 2.00 | 440 | 2.62 | Contact | Contact | Contact | Contact |
| 3.00 | 440 | 3.94 | Contact | Contact | Contact | Contact |
460Y/266 V Secondary
600V Wye primary (input) x 460Y/266 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 460Y/266 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 460Y/266 | 0.44 | Contact | Contact | Contact | Contact |
| 0.50 | 460Y/266 | 0.63 | Contact | Contact | Contact | Contact |
| 0.75 | 460Y/266 | 0.94 | Contact | Contact | Contact | Contact |
| 1.00 | 460Y/266 | 1.26 | Contact | Contact | Contact | Contact |
| 1.50 | 460Y/266 | 1.88 | Contact | Contact | Contact | Contact |
| 2.00 | 460Y/266 | 2.51 | Contact | Contact | Contact | Contact |
| 3.00 | 460Y/266 | 3.77 | Contact | Contact | Contact | Contact |
460 V Secondary
600V Wye primary (input) x 460 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 460 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 460 | 0.44 | Contact | Contact | Contact | Contact |
| 0.50 | 460 | 0.63 | Contact | Contact | Contact | Contact |
| 0.75 | 460 | 0.94 | Contact | Contact | Contact | Contact |
| 1.00 | 460 | 1.26 | Contact | Contact | Contact | Contact |
| 1.50 | 460 | 1.88 | Contact | Contact | Contact | Contact |
| 2.00 | 460 | 2.51 | Contact | Contact | Contact | Contact |
| 3.00 | 460 | 3.77 | Contact | Contact | Contact | Contact |
480Y/277 V Secondary
600V Wye primary (input) x 480Y/277 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 480Y/277 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 480Y/277 | 0.42 | Contact | Contact | Contact | Contact |
| 0.50 | 480Y/277 | 0.6 | Contact | Contact | Contact | Contact |
| 0.75 | 480Y/277 | 0.9 | Contact | Contact | Contact | Contact |
| 1.00 | 480Y/277 | 1.2 | Contact | Contact | Contact | Contact |
| 1.50 | 480Y/277 | 1.8 | Contact | Contact | Contact | Contact |
| 2.00 | 480Y/277 | 2.41 | Contact | Contact | Contact | Contact |
| 3.00 | 480Y/277 | 3.61 | Contact | Contact | Contact | Contact |
480 V Secondary
600V Wye primary (input) x 480 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 480 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 480 | 0.42 | Contact | Contact | Contact | Contact |
| 0.50 | 480 | 0.6 | Contact | Contact | Contact | Contact |
| 0.75 | 480 | 0.9 | Contact | Contact | Contact | Contact |
| 1.00 | 480 | 1.2 | Contact | Contact | Contact | Contact |
| 1.50 | 480 | 1.8 | Contact | Contact | Contact | Contact |
| 2.00 | 480 | 2.41 | Contact | Contact | Contact | Contact |
| 3.00 | 480 | 3.61 | Contact | Contact | Contact | Contact |
600Y/347 V Secondary
600V Wye primary (input) x 600Y/347 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 600Y/347 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 600Y/347 | 0.34 | Contact | Contact | Contact | Contact |
| 0.50 | 600Y/347 | 0.48 | Contact | Contact | Contact | Contact |
| 0.75 | 600Y/347 | 0.72 | Contact | Contact | Contact | Contact |
| 1.00 | 600Y/347 | 0.96 | Contact | Contact | Contact | Contact |
| 1.50 | 600Y/347 | 1.44 | Contact | Contact | Contact | Contact |
| 2.00 | 600Y/347 | 1.92 | Contact | Contact | Contact | Contact |
| 3.00 | 600Y/347 | 2.89 | Contact | Contact | Contact | Contact |
575 V Secondary
600V Wye primary (input) x 575 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 575 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 575 | 0.35 | Contact | Contact | Contact | Contact |
| 0.50 | 575 | 0.5 | Contact | Contact | Contact | Contact |
| 0.75 | 575 | 0.75 | Contact | Contact | Contact | Contact |
| 1.00 | 575 | 1 | Contact | Contact | Contact | Contact |
| 1.50 | 575 | 1.51 | Contact | Contact | Contact | Contact |
| 2.00 | 575 | 2.01 | Contact | Contact | Contact | Contact |
| 3.00 | 575 | 3.01 | Contact | Contact | Contact | Contact |
600 V Secondary
600V Wye primary (input) x 600 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer.
| 600V Wye Primary - 600 Secondary | ||||||
| kVA | Output Voltages | Output Amps | Open Units | Enclosed Units | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| 0.35 | 600 | 0.34 | Contact | Contact | Contact | Contact |
| 0.50 | 600 | 0.48 | Contact | Contact | Contact | Contact |
| 0.75 | 600 | 0.72 | Contact | Contact | Contact | Contact |
| 1.00 | 600 | 0.96 | Contact | Contact | Contact | Contact |
| 1.50 | 600 | 1.44 | Contact | Contact | Contact | Contact |
| 2.00 | 600 | 1.92 | Contact | Contact | Contact | Contact |
| 3.00 | 600 | 2.89 | Contact | Contact | Contact | Contact |